İZMİR İMPLANTOLOJİ
DİŞ HEKİMİ DR. MURAT SÜTPİDELER, PROTEZ UZMANI - PROSTODONTIST, DDS, PhD
İZMİR İMPLANTOLOJİ
 
İMPLANT & PROTEZ & ESTETİK DİŞHEKİMLİĞİ

DİŞHEKİMLİĞİ UYGULAMALARI

İMPLANTOLOJİ

İmplant Cerrahisi

İmplant Uygulamaları 

ESTETİK DİŞHEKİMLİĞİ

Diş Beyazlatma (Bleaching)

Laminate Veneer (Porselen)

 Zirkonyum Kron Köprü

 Tam Seramik Kron Köprü

 Adeziv Uygulamalar

  PROTEZ  

 Porselen Kron Köprü

 Hassas Baðlantýlý Protez

 Hareketli Bölümlü Protez

 Tam Protez

 

Yayınlar

* Neutral Zone in Partial Dentures ,  Ege University School of Dentistry, Izmir – 1987.

* Advantages of Registration of Neutral Zone ,Journal of Ege University  School of  Dentistry  Izmir - 1988 .

* Post –Core Applications by Using Different Post Designs ,  Lecture , Ege University School of   Dentistry , Izmir – 1989.

* Finite Element Analysis in Different Post- Core Designs ,  Doctorate (PhD ) Thesis ,Ege University School of Dentistry ,Izmir , 1993.

* The Importance of Root Canal Treatment and Post –Core Applications in the Space Medicine ,  Lecture , Space Medicine Center , Eskisehir, 2001.

* Finite Element Analysis in Dentistry , Conference, Dec. 2002 , Mayo Clinic, Rochester, MN, USA.

* Evaluation of Force Transmission to Endosseous Implants Using Straight Line or Offset Configuration Through Finite Element Analysis, Conference , Sept. 2003. Mayo Clinic , Rochester, MN, USA.

* Finite Element Analysis of Effect of Prosthesis Height, Angle of Force Application and Implant Offset on Supporting Bone. (International Journal of Oral Maxillofacial Implants 2004, 19:819-825).

* Finite Element Analysis of Force Transmission to Bone Supporting Endosseous  Implants , 82nd General Session of the IADR, Honolulu, Hawaii, USA, March 10 – 13, 2004.

* Evaluation of Force Transmission to Endosseous Implants Using Straight Line or Offset  Configuration Through FEA , European Society of Biomechanics Meeting , ‘s  Hertogenbosch, Holland , 3-6 July, 2004.                        

* Stress Distribution of Various Glass Fiber-reinforced Post designs .28th Annual Conference European Prosthodontic Association,  Kusadasi, Izmir, Turkey, Sept. 16- 18, 2004.

* Evaluation of Force Transmission to Bone Supporting Endosseous Implants , 84th General Session of the International Association for Dental Research , Brisbane, AUSTRALIA, June 28– July 1, 2006

* Influence of implant shape and placement design to stress distribution, 86th  General Session of the International Association for Dental Research, Toronto, CANADA, July 2-5, 2008 .

“Site içeriğinde bulunan bilgiler bilgilendirmek içindir, bu bilgilendirme kesinlikle hekimin hastasını tıbbi amaçla muayene etmesi veya tanı koyması yerine geçmez”.